Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Int J Retina Vitreous ; 10(1): 33, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38605358

RESUMO

BACKGROUND: Describe complications and clinical outcomes of heavy silicone oil (HSO) Oxane HD® use as an alternative to overcome the challenges of performing vitrectomy to treat tractional and rhegmatogenous retinal detachments with proliferative vitreoretinopathy (PVR). METHODS: A retrospective, observational study was performed on patients from one center from August 2014 to Aug 2023. It was included patients who underwent surgery using HSO Oxane HD® to treat rhegmatogenous retinal detachment with PVR or mixed tractional and rhegmatogenous diabetic retinal detachment. Severely ill patients who could not attend to follow up were excluded. The primary outcome was successful retinal attachment at first postoperative month. A descriptive analysis was performed. RESULTS: Among the 31 patients, 29 (93.5%) underwent surgeries due to rhegmatogenous retinal detachment and two (6.5%) for diabetic retinal detachment. The primary anatomic success was achieved in 27 (87.1%) patients. At the final visit, 17 (56.6%) had vision better than 20/400 (range, 20/30 to light perception). The vision was stable or improved in 22 (76.8%) patients at the end of follow-up. Nineteen (61.3%) patients required hypotensive eye drops after HSO use and twelve (38.7%) still required hypotensive eye drops at the final follow-up; three (9.7%) patients required additional glaucoma surgeries. CONCLUSIONS: HSO is safe and useful for complex retinal detachments cases specially with inferior tears and PVR. Ocular hypertension is frequent and usually clinically controlled with hypotensive eyedrops. Close postoperatively follow-up is advised due to the ocular complications, particularly elevated intraocular pressure and emulsification.

2.
Int J Retina Vitreous ; 9(1): 64, 2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37872580

RESUMO

The main drawback for the use of heavy silicone oil (HSO) Oxane HD is the difficulties it presents during removal. It differs from conventional silicone oil removal because it progressively concentrates in the posterior pole during the removal because of its heavier than water density. We describe a technique to facilitate proper HSO Oxane HD removal and minimize residual posterior bubbles and intraoperative complications. We describe our pearls for removing HSO to obtain the optimal results. A concern associated with HSO is the difficulty it presents when it is removed. However, this can be overcome by appropriate modification of surgical techniques during removal to limit intraoperative complications.

3.
Sci Rep ; 13(1): 18031, 2023 10 21.
Artigo em Inglês | MEDLINE | ID: mdl-37865682

RESUMO

Our purpose was to compare postoperative infectious endophthalmitis rates before and after the introduction of antibiotic prophylaxis via intracameral with cefuroxime (ATB-P IC) in a high-volume cataract surgery service. Retrospective cohort study considering patients who underwent cataract surgery at Ophthal Hospital Especializado, São Paulo, Brazil, from January/2011 to December/2019. Patients operated from 2013 to 2019 comprised the ATB-P IC group while those operated from 2011 to 2013 formed the control group without the ATB-P IC protocol. A total of 23,184 cataract surgeries were included, with 6,207 in the Control Group and 16,977 in the ATB-P Group. A significantly higher rate of endophthalmitis was observed in the control group (0.0967%) when compared to the ATB-P group (0.0177%) (p = 0.014). Surgeries performed with ATB-P showed 80% less chance of reported endophthalmitis (OR = 0.20; 95% CI 0.05-0.72; p = 0.014) than those without ATB-P. Of the six cases confirmed by culture in the control group, all tested positive for Pseudomonas aeroginosa and the only case confirmed by culture in the ATB-P group was positive for Staphylococcus epidermidis. Our findings strongly support the use of intracameral antibiotic prophylaxis with cefuroxime to reduce postoperative infectious endophthalmitis rates, and we recommend its incorporation into cataract surgery protocols.


Assuntos
Extração de Catarata , Catarata , Endoftalmite , Humanos , Cefuroxima/uso terapêutico , Antibioticoprofilaxia , Estudos Retrospectivos , Brasil , Extração de Catarata/efeitos adversos , Antibacterianos/uso terapêutico , Endoftalmite/epidemiologia , Endoftalmite/etiologia , Endoftalmite/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Câmara Anterior
4.
Arq. bras. oftalmol ; 86(3): 206-209, May 2023. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1439370

RESUMO

ABSTRACT Purpose: To evaluate the profile of emergency eye-related visits at a reference eye hospital in Sao Paulo during the first months of the quarantine due to the coronavirus disease (COVID-19) pandemic and to compare it with that in the same period of the previous year. Methods: Data were obtained from the emergency department of Ophthal Hospital Especializado, Sao Paulo, Brazil. All the cases registered between March 23 and May 19, 2020, were included in the study as Group 2020. The cases registered between March 23 and May 19, 2019, were included in the study as Group 2019. Frequency tables were used for the descriptive analyses. The chi-square and Fisher exact tests were applied to compare categorical variables between the groups. Results: We observe a decrease of 46.15% in the number of cases during the COVID-19 pandemic in 2020 compared with the same period in 2019. We observed a significant increase in the incidence rates of the following pathologies in 2020 compared with 2019: eyelid disorders (12.3%), corneal disorders (97.1%), retinal pathologies (173.1%), refraction (62.9%), glaucoma (acute and chronic; 43.9%), scleral alterations (68.8%), trauma (39.3%), herpes (54.7%), and cataracts (549.9%). On the other hand, the incidence rates of the following disorders decreased: conjunctivitis (-33.4%), disorders of lacrimal system (-81.0%), iridocyclitis (-39.9%), and postoperative visits (-80.1%). Conclusion: During the early phase of the COVID-19 pandemic, we observed a drastic decrease in the number of patients who visited the emergency eye service. The main reasons for visiting were also changed, with higher frequencies of high-severity cases such as retina disturbances, cornea disturbances, glaucoma, and trauma and lower frequencies of transmittable conditions such as conjunctivitis.


RESUMO Objetivos: Avaliar o perfil das consultas de emergência oftalmológicas durante os primeiros meses de quarentena por pandemia de covid-19 em um hospital oftalmológico de referência em São Paulo e compará-lo com o mesmo período do ano anterior. Métodos: Os dados foram extraídos do serviço de emergência do Hospital Ophthal Especializado, São Paulo, Brasil. Todos os casos registrados entre 23 de março e 19 de maio de 2020 foram incluídos no estudo como Grupo 2020. Os casos registrados entre 23 de março e 19 de maio de 2019 foram incluídos no estudo como Grupo de 2019. Tabelas de frequência foram utilizadas para análises descritivas. Os testes Qui-quadrado e Exato de Fisher foram aplicados para comparar variáveis categóricas entre os grupos. Resultados: Observamos uma diminuição de 46,15% no número de casos durante a pandemia Covid-19 em 2020 quando comparado ao mesmo período sem pandemia em 2019. Foi observado um aumento significativo nos achados de pálpebra (+12,3%), córnea (+97,1%), retina (+173,1%), refração (+62,9%), glaucoma (+43,9%), esclera (+68,8%), trauma (+39,3%), herpes (+54,7%) e catarata (+549,9%) em 2020 quando comparado para 2019. Por outro lado, houve redução nos casos de conjuntivite (-33,4%), transtornos do aparelho lacrimal (-81,0%), iridociclite (-39,9%) e consultas pós-operatórias (-80,1%). Conclusão: durante a fase inicial da pandemia Covid-19, foi observada uma redução drástica no número de pacientes que procuram o serviço de emergência ocular. Houve também uma mudança nos principais motivos para visitas com frequências mais altas de casos de alta gravidade como distúrbios da retina, distúrbios da córnea, glaucoma e trauma, e frequências mais baixas de condições transmissíveis como conjuntivite.

5.
Can J Ophthalmol ; 2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-36965507

RESUMO

OBJECTIVE: To compare long-term outcomes of eyes undergoing Ahmed glaucoma drainage implants in the anterior chamber versus the pars plana.Retrospective cohort study. PARTICIPANTS: Operated patients were divided into anterior-chamber or pars plana groups. METHODS: Follow-up data included intraocular pressure (IOP), need for antiglaucoma medications (AGMs), and postoperative complications. Treatment success was evaluated based on the following criteria: IOP ≤21 mm Hg and no AGM use, IOP ≤21 mm Hg with or without AGM use, IOP ≤18 mm Hg and no AGM use, IOP ≤18 mm Hg with or without AGM use, IOP ≤15 mm Hg and no AGM use, and IOP ≤15 mm Hg with or without AGM use. RESULTS: A total of 170 eyes were selected and split into an anterior-chamber group (n = 57) and a pars plana group (n = 113). No differences between groups were found on the decrease in IOP (p = 0.612) or number of AGMs (p = 0.695) in the postoperative period. No differences regarding corneal decompensation (p = 0.554) or retinal detachment (p = 0.168) were observed between groups. The 1-year success rates for all the criteria were, respectively, 89%, 96%, 88%, 92%, 88% and 90%; the 3-year success rates for all the criteria were, respectively, 33%, 61%, 32%, 55%, 28%, and 45%; and the 5-year success rates for all the criteria were, respectively, 7%, 48%, 7%, 36%, 4% and 17%. CONCLUSIONS: No differences between the groups were observed for long-term outcomes of IOP, AGM use, or postoperative complications. Success rates were comparable between groups, decreased along the follow-up time, and were higher when associated with AGM use.

6.
Eye (Lond) ; 37(14): 2909-2914, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36782058

RESUMO

BACKGROUND/OBJECTIVES: Tremor and expertise are potentially influenced variables in vitreoretinal surgery. We investigated whether surgeon experience impacts the association of microsurgical performance with caffeine and ß-blockers weight-adjusted intake. SUBJECTS/METHODS: Novice and senior surgeons (<2 and >10 practice years, respectively) were recruited in this self-controlled, cross-sectional study. A simulator's task sequence was repeated over 2 days, 30 min after the following exposures: day 1, placebo, 2.5 mg/kg caffeine, 5.0 mg/kg caffeine, and 0.6 mg/kg propranolol; and day 2, placebo, 0.2 mg/kg propranolol, 0.6 mg/kg propranolol, and 5.0 mg/kg caffeine. Outcomes were total score (0-700, worst-best), simulation time (minutes), intraocular trajectory (centimeters), and tremor-specific score (0-100, worst-best). RESULTS: We recruited 15 novices (9 men [60%], 1.33 ± 0.49 practice years) and 11 seniors (8 men [72.7%], 16.00 ± 4.24 practice years). Novices performed worse after 2.5 mg/kg caffeine and improved following 0.2 mg/kg propranolol in total score (557 vs. 617, p = 0.009), trajectory (229.86 vs. 208.07, p = 0.048), time (14.9 vs. 12.7, p = 0.048), and tremor-score (55 vs. 75, p = 0.009). Surgical performance improved with propranolol post-caffeine but remained worse than 0.2 mg/kg propranolol in total score (570 vs. 617, p = 0.014), trajectory (226.59 vs. 208.07, p = 0.033), and tremor-score (50 vs. 75, p = 0.029). Seniors' tremor-score was lower after 2.5 mg/kg caffeine compared to 0.2 mg/kg propranolol (8 vs. 37, p = 0.015). Tremor-score following propranolol post-caffeine remained inferior to 0.6 mg/kg propranolol alone (17 vs. 38, p = 0.012). CONCLUSION: While caffeine and propranolol were associated with performance changes among novices, only tremor was affected in seniors, without dexterity changes. The pharmacologic exposure impact on surgical dexterity seems to be offset by increased experience.


Assuntos
Cafeína , Cirurgiões , Humanos , Masculino , Antagonistas Adrenérgicos beta/farmacologia , Antagonistas Adrenérgicos beta/uso terapêutico , Cafeína/farmacologia , Estudos Transversais , Método Duplo-Cego , Propranolol/farmacologia , Propranolol/uso terapêutico , Retina , Tremor/tratamento farmacológico
7.
Arq Bras Oftalmol ; 86(3): 206-209, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35319652

RESUMO

PURPOSE: To evaluate the profile of emergency eye-related visits at a reference eye hospital in Sao Paulo during the first months of the quarantine due to the coronavirus disease (COVID-19) pandemic and to compare it with that in the same period of the previous year. METHODS: Data were obtained from the emergency department of Ophthal Hospital Especializado, Sao Paulo, Brazil. All the cases registered between March 23 and May 19, 2020, were included in the study as Group 2020. The cases registered between March 23 and May 19, 2019, were included in the study as Group 2019. Frequency tables were used for the descriptive analyses. The chi-square and Fisher exact tests were applied to compare categorical variables between the groups. RESULTS: We observe a decrease of 46.15% in the number of cases during the COVID-19 pandemic in 2020 compared with the same period in 2019. We observed a significant increase in the incidence rates of the following pathologies in 2020 compared with 2019: eyelid disorders (12.3%), corneal disorders (97.1%), retinal pathologies (173.1%), refraction (62.9%), glaucoma (acute and chronic; 43.9%), scleral alterations (68.8%), trauma (39.3%), herpes (54.7%), and cataracts (549.9%). On the other hand, the incidence rates of the following disorders decreased: conjunctivitis (-33.4%), disorders of lacrimal system (-81.0%), iridocyclitis (-39.9%), and postoperative visits (-80.1%). CONCLUSION: During the early phase of the COVID-19 pandemic, we observed a drastic decrease in the number of patients who visited the emergency eye service. The main reasons for visiting were also changed, with higher frequencies of high-severity cases such as retina disturbances, cornea disturbances, glaucoma, and trauma and lower frequencies of transmittable conditions such as conjunctivitis.


Assuntos
COVID-19 , Conjuntivite , Glaucoma , Humanos , COVID-19/epidemiologia , Pandemias , Brasil/epidemiologia , Hospitais , Serviço Hospitalar de Emergência , Conjuntivite/epidemiologia , Estudos Retrospectivos
8.
Arq. bras. oftalmol ; 86(6): e20230073, 2023. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1520203

RESUMO

ABSTRACT This is a case report involving a 56-year-old male patient with a history of pars plana vitrectomy due to a rhegmatogenous retinal detachment in the right eye that resulted in the implantation of a drainage device after the patient developed secondary glaucoma. Two years after the device's implantation, the patient was referred to our care as his visual acuity had decreased to 20/200 (1.00 LogMAR). At the fundus evaluation, a choroidal amelanotic elevation was observed at the upper temporal equator, and a potential diagnosis was made of amelanotic choroidal melanoma. The ultrasound exam visualized the patient's implanted superotemporal justabulbar drainage device, which revealed a transscleral communication from the plate fibrocapsular's draining space to the suprachoroidal space (fistula). The ultrasound also revealed a focal pocket of choroidal detachment in the patient's superotemporal region, simulating an amelanotic choroidal melanoma. A new pars plana vitrectomy was performed to remove the internal limiting membrane without repercussions at the fistula site. The patient's recovery progressed well, and he regained a visual acuity of 20/70 (0.55 LogMAR). To the best of our knowledge, this is the first case report of this condition.


RESUMO Relato de caso de paciente 56 anos, sexo masculino, com histórico de vitrectomia via pars plana por descolamento de retina em olho direito e posterior implante de dispositivo de drenagem por glaucoma secundário. Dois anos após o procedimento foi encaminhado ao serviço por baixa de acuidade visual (AV) de 20/200 (1.00 LogMAR). À fundoscopia, observou-se uma elevação amelanótica temporal no equador com hipótese diagnóstica de melanoma de coroide amelanótico. O exame de ultrassom mostrou implante de dispositivo de drenagem justabulbar temporal superior com comunicação transescleral para espaço subcoroidal (fístula), sugerindo bolsão focal de descolamento de coroide em equador temporal superior simulando melanoma de coroide amelanótico. O paciente foi abordado cirurgicamente devido membrana epirretiniana com nova vitrectomia via pars plana para peeling de membrana limitante interna, sem repercussões no local da fístula, evoluindo bem com acuidade visual de 20/70 (0.55 LogMAR). Ao nosso conhecimento, este é o primeiro caso relatado nessa condição.

9.
Arq Bras Oftalmol ; 2022 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-35544943

RESUMO

This is a case report involving a 56-year-old male patient with a history of pars plana vitrectomy due to a rhegmatogenous retinal detachment in the right eye that resulted in the implantation of a drainage device after the patient developed secondary glaucoma. Two years after the device's implantation, the patient was referred to our care as his visual acuity had decreased to 20/200 (1.00 LogMAR). At the fundus evaluation, a choroidal amelanotic elevation was observed at the upper temporal equator, and a potential diagnosis was made of amelanotic choroidal melanoma. The ultrasound exam visualized the patient's implanted superotemporal justabulbar drainage device, which revealed a transscleral communication from the plate fibrocapsular's draining space to the suprachoroidal space (fistula). The ultrasound also revealed a focal pocket of choroidal detachment in the patient's superotemporal region, simulating an amelanotic choroidal melanoma. A new pars plana vitrectomy was performed to remove the internal limiting membrane without repercussions at the fistula site. The patient's recovery progressed well, and he regained a visual acuity of 20/70 (0.55 LogMAR). To the best of our knowledge, this is the first case report of this condition.

10.
Rev. bras. oftalmol ; 81: e0004, 2022. tab, graf
Artigo em Português | LILACS | ID: biblio-1357124

RESUMO

RESUMO A acurácia do cálculo da lente intraocular não é perfeita, podendo ser comuns erros refrativos pós-operatórios, especialmente em pacientes submetidos à cirurgia refrativa prévia ou na presença de córneas assimétricas. O poder corneano após cirurgia refrativa pode ser medido com maior acurácia utilizando o mapa de poder óptico total na zona central de 4mm, com Orbscan II ou pelo mapa equivalent keratometric reading disponível no pentacam, com medidas centrais de 1,0, 2,0, 3,0 e 4,5mm. O objetivo desta série de casos é demonstrar a abordagem de quatro olhos em condições especiais corneanas, por meio do equivalent keratometric reading do pentacam para mensuração do poder corneano e o utilizando na biometria, em comparação com possíveis resultados obtidos com outras estratégias. Os quatro olhos foram submetidos a procedimentos refrativos prévios, e a lente intraocular escolhida a partir do uso do poder corneano calculado pelo equivalent keratometric reading mostrou excelentes resultados pós-operatórios.


ABSTRACT The accuracy of the intraocular lens calculation is not perfect, and postoperative refractive errors are common, especially in patients who have undergone previous refractive surgery or in presence of asymmetric corneas. Corneal power after refractive surgery can be more accurately measured using the total optical power map in the 4-mm central zone, by means of Orbscan II or equivalent keratometric reading map available on pentacam, with central measurements of 1.0, 2.0, 3.0 and 4.5 mm. The purpose of this case series is to demonstrate four approaches performed in special corneal conditions, using pentacam equivalent keratometric reading to measure corneal power and biometrics, and comparing with possible results obtained with other strategies. The four eyes were submitted to previous refractive procedures, and the intraocular lens chosen from the use of the corneal power calculated by equivalent keratometric reading showed excellent postoperative results.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Biometria/métodos , Implante de Lente Intraocular , Procedimentos Cirúrgicos Refrativos , Refração Ocular/fisiologia , Erros de Refração/diagnóstico , Erros de Refração/fisiopatologia , Catarata/diagnóstico , Acuidade Visual , Topografia da Córnea , Microscopia com Lâmpada de Fenda , Lentes Intraoculares
11.
Arq. bras. oftalmol ; 76(6): 341-344, nov.-dez. 2013. tab
Artigo em Português | LILACS | ID: lil-701283

RESUMO

OBJETIVOS: Estudar a habilidade diagnóstica do tomógrafo retiniano de Heidelberg (HRT II), GDx analisador de fibras nervosas (GDx), perimetria azul-amarelo (SWAP), tecnologia de frequência duplicada (FDT) isoladamente e em conjunto no diagnóstico do glaucoma. MÉTODOS: Sessenta glaucomatosos e 60 pacientes normais foram submetidos a exames de HRT II, GDx, SWAP e FDT. HRT foi considerado alterado quando pelo menos uma região do anel neurorretiniano esteve fora dos limites da normalidade, conforme a análise de regressão de Moorfields. GDx alterado foi definido quando pelo menos um índice foi considerado pelo programa do equipamento como fora dos limites normais, excluindo-se o índice simetria, ou ainda quando no gráfico "the deviation from normal graph" apareceu um quadrante com significância abaixo de 5%. O FDT foi considerado anormal quando pelo menos uma região testada apresentou-se com defeito severo ou com a presença de dois defeitos moderados contíguos. Para o SWAP foram adotados os critérios de anormalidade propostos por Anderson. Análise de regressão logística foi realizada. RESULTADOS: Quando foram estudadas as tecnologias isoladamente, a análise de regressão logística apresentou melhores índices de razão das chances para glaucoma com exames positivos para o HRT (22,49), seguido pelo SWAP (21,71). FDT (3,97) e GDx (2,73). Quando se associaram exames positivos de diferentes tecnologias, as razões das chances aumentaram. Nos casos com exames de HRT, FDT e SWAP fora dos limites normais, a razão das chances foi de 252,6 e com HRT, SWAP e GDx alterados, 173,1. Quando associamos exames positivos de diferentes tecnologias, a razão das chances dos pacientes serem glaucomatosos aumentou consideravelmente, chegando a 689,7 com todos os exames fora dos limites normais, o que ocorreu em 26 pacientes deste estudo. CONCLUSÕES: A análise de regressão logística confirmou que a presença de exames alterados de HRT ou SWAP apresentam as maiores razões das chances de glaucoma. A associação de exames alterados aumentou a razão das chances, principalmente, quando o HRT e o SWAP estavam fora dos limites normais.


PURPOSES: In this research was studied the diagnostic ability of the Heidelberg Retinal Tomograph (HRT II), GDx nerve fiber analyzer (GDx), Short-wavelenght Automated Perimetry (SWAP) and Frequency-doubling technology (FDT), all of them together and also separately in the diagnosis of glaucoma. METHODS: Sixty glaucomatous patients and 60 normal ones were submitted to examination with the technology of HRT II, GDx, FDT and SWAP. In the interpretation of HRT, based on the Moorfields regression analysis, were considered abnormal when at least one area of the neuroretinal ring was outside the bounds of normality. GDx was defined as altered, when it was observed that at least one index was considered by equipment program as outside of normal limits, excluding the index symmetry, or when "the deviation from normal graph" appeared a quadrant with significance below 5%. The FDT was considered abnormal when at least one region tested presented with severe defects, or two contiguous moderate defects in at least two reliable tests. For SWAP was adopted the abnormality criteria proposed by Anderson. Logistic regression analysis was performed. RESULTS: When the technologies were studied separately, the Logistic regression analysis showed better odds ratio rates to test positive for glaucoma with HRT (22.49), followed by EAP (21.71), FDT (3.97) and GDx (2.73). When positive tests were associated with different technologies, the odds ratios increased. In cases with HRT, FDT and PAA tests, outside normal bounds, the odds ratio was 252.6. Concerning the HRT, GDx and PAA the result have changed to 173.1. When we associate positive tests from different technologies, the odds ratio of glaucomatous patients have increased considerably, reaching 689.7 with all the tests outside normal bounds, which have happened with 26 patients of this study. CONCLUSIONS: The Logistic Regression analysis confirmed that the abnormal tests of HRT and PAA have shown to be the highest reasons for glaucoma occurrence. The association of abnormal tests increased the odds ratio, especially when the HRT and PAA were out of normal bounds.


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Glaucoma/diagnóstico , Oftalmoscopia/métodos , Polarimetria de Varredura a Laser/métodos , Testes de Campo Visual/métodos , Estudos de Casos e Controles , Pressão Intraocular/fisiologia , Modelos Logísticos , Disco Óptico/patologia , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Acuidade Visual/fisiologia
12.
Arq Bras Oftalmol ; 76(6): 341-4, 2013.
Artigo em Português | MEDLINE | ID: mdl-24510079

RESUMO

PURPOSES: In this research was studied the diagnostic ability of the Heidelberg Retinal Tomograph (HRT II), GDx nerve fiber analyzer (GDx), Short-wavelenght Automated Perimetry (SWAP) and Frequency-doubling technology (FDT), all of them together and also separately in the diagnosis of glaucoma. METHODS: Sixty glaucomatous patients and 60 normal ones were submitted to examination with the technology of HRT II, GDx, FDT and SWAP. In the interpretation of HRT, based on the Moorfields regression analysis, were considered abnormal when at least one area of the neuroretinal ring was outside the bounds of normality. GDx was defined as altered, when it was observed that at least one index was considered by equipment program as outside of normal limits, excluding the index symmetry, or when "the deviation from normal graph" appeared a quadrant with significance below 5%. The FDT was considered abnormal when at least one region tested presented with severe defects, or two contiguous moderate defects in at least two reliable tests. For SWAP was adopted the abnormality criteria proposed by Anderson. Logistic regression analysis was performed. RESULTS: When the technologies were studied separately, the Logistic regression analysis showed better odds ratio rates to test positive for glaucoma with HRT (22.49), followed by EAP (21.71), FDT (3.97) and GDx (2.73). When positive tests were associated with different technologies, the odds ratios increased. In cases with HRT, FDT and PAA tests, outside normal bounds, the odds ratio was 252.6. Concerning the HRT, GDx and PAA the result have changed to 173.1. When we associate positive tests from different technologies, the odds ratio of glaucomatous patients have increased considerably, reaching 689.7 with all the tests outside normal bounds, which have happened with 26 patients of this study. CONCLUSIONS: The Logistic Regression analysis confirmed that the abnormal tests of HRT and PAA have shown to be the highest reasons for glaucoma occurrence. The association of abnormal tests increased the odds ratio, especially when the HRT and PAA were out of normal bounds.


Assuntos
Glaucoma/diagnóstico , Oftalmoscopia/métodos , Polarimetria de Varredura a Laser/métodos , Testes de Campo Visual/métodos , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Pressão Intraocular/fisiologia , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Disco Óptico/patologia , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Acuidade Visual/fisiologia
13.
Clin Ophthalmol ; 5: 933-6, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21792281

RESUMO

OBJECTIVE: To compare the pattern of intraocular pressure (IOP) reduction following selective laser trabeculoplasty (SLT) versus argon laser trabeculoplasty (ALT) in open-angle glaucoma (OAG) patients, and to investigate the ability of initial IOP reduction to predict mid-term success. METHODS: A prospective, nonrandomized, interventional case series was carried out. Consecutive uncontrolled OAG glaucoma patients underwent SLT or ALT; the same preoperative medical regimen was maintained during follow-up. Data collected included age, type of OAG, pre- and postoperative IOP, number of glaucoma medications, and surgical complications. Post-treatment assessments were scheduled at day 1 and 7 and months 1, 3, and 6. RESULTS: A total of 45 patients (45 eyes) were enrolled [SLT group (n = 25); ALT group (n = 20)]. Groups were similar for age, baseline IOP, and number of glaucoma medications (P ≥ 0.12). We found no significant differences in mean IOP reduction between SLT (5.1 ± 2.5 mmHg; 26.6%) and ALT (4.4 ± 2.8 mmHg; 22.8%) groups at month 6 (P = 0.38). Success rates (IOP ≤ 16 mmHg and IOP reduction ≥25%) at last follow-up visit were similar for SLT (72%) and ALT (65%) groups (P = 0.36). Comparing the pattern of IOP reduction (% of IOP reduction at each visit) between groups, we found a greater effect following SLT compared with ALT at day 7 (23.7% ± 13.7% vs 8.1% ± 9.5%; P < 0.001). No significant differences were observed at other time points (P ≥ 0.32). Additionally, the percentage of IOP reduction at day 7 and at month 6 were significantly correlated in the SLT group (R(2) = 0.36; P < 0.01), but not in the ALT group (P = 0.89). Early postoperative success predicted late success in most SLT cases (82%). No serious complications were observed. CONCLUSION: Although mid-term results suggest SLT and ALT as effective and equivalent alternatives, a greater initial IOP reduction was observed following SLT. In addition, the initial IOP reduction was a good predictor of mid-term success in patients undergoing SLT, but not ALT.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...